1H-2 Lubricating system (6WG1 (Common rail)) Lubricating system Service Precautions Always apply the correct amount of liquid gasket. Care must be taken, as over-application of liquid gasket can cause burning due to a blocked oil gallery or oil jet. Under-application of liquid gasket can cause oil or water leakage. Always re-apply the liquid gasket upon itself when starting and finishing liquid gasket application. Each time you disassemble parts that use liquid gasket, completely remove the old gasket residue from each of the parts and matching sections using a scraper, then clean each of the parts to completely remove oil, water, and dirt etc. from the various surfaces.
Using the specified type of liquid gasket, apply new liquid gasket to each of the surfaces before re-assembling the parts. Explanation of functions and operations The lubricating system consists of an oil pump, full flow filter, water cooled oil cooler, and oil jet for piston cooling. Lubricating system diagram