Komatsu — 4.8.9.b CHANGING THE HYDRAULIC SYSTEM OIL AND CLEANING THE SUCTION FILTER

MAINTENANCE PROCEDURE 4.8.9.b CHANGING THE HYDRAULIC SYSTEM OIL AND CLEANING THE SUCTION FIL- TER q On machines filled with synthetic biodegradable hy- draulic oil type HEES the oil must be changed after the first 500 hours of operation and successively every 1000 hours, and in any case at least once a year. RWA37070 q Lower the loader arm completely, lower the bucket to the ground, stop the engine, release the residual pres- sures from the work equipment circuits (by operating the controls more than once) and lock the safety bars (see "3.3.5 pos. 1 - SAFETY BARS"). q Let the oil cool down until it reaches 40-45єC before car- rying out any maintenance operation.

q Immediately clean any area dirty with oil. q Oils, filters, coolants and batteries are considered spe- cial waste and must be collected and disposed of ac- cording to the anti-pollution regulations in force. Stop the machine on a firm and level surface, lower the equip- ment to the ground, stop the engine and release the residual pressures from the work equipment circuits by operating the controls more than once. Raise the engine hood (see "3.5.1 ENGINE HOOD") and open the rear panel (see "3.5.2 REAR PANEL"). 1 - Slowly loosen the filling cap (1) to release the residual pressure from the tank and then remove it.

2 - Remove the lower plug (2) and let the used oil flow out completely, gathering it in a container with suitable capac- ity. Use a 12 mm hexagon spanner. 2 RWA34230 198 CAUTION WARNING