Liebherr — R934B_en_sn_17227.mdi

In case the lubrication pump does not work, all lubrication points connected to the centralized system may be lubricated via the lube fitting 25 (fig. 46) using a lubrication gun. In this case, press daily or per working shift approx. 200 cm 3 grease into the fitting 25. TO REFILL THE GREASE CONTAINER The grease level in the container 13 of the pump must be checked weekly, and if necessary, the container refilled. See the lubricant chart for grease specification. The refilling of the grease container should only be done via the special fitting 21. Insert a grease cartridge in the special filling pump 31 (Id. No.

10009239), connect the pump to the fitting 21 and push the whole content of the cartridge into the container 13 (fig. 46). Avoid refilling via the upper tank cover 23, since it could create an air pocket in the container and cause the pump to run dry. For indication of ordering number of grease cartridges, refer to page 5.9. Without the special filling pump 31 or grease cartridges, the container 13 must be refilled through the grease fitting 22 (fig. 46), using a grease gun. 46 5.22