Kaiyi — Kaiyi Hydraulic Systems Maintenance Manual

12. HYDRAULIC OIL FILTER INSPECTION 12. HYDRAULIC OIL FILTER INSPECTION PROCEDURE PROCEDURE 1) Lower the bucket to the ground, stop the engine, move the control lever back and forth several times, and clean all over the upper surface of the hydraulic oil tank. 2) Remove the bolts and take out the filter case cover and O-ring. Cover 3) Remove the spring and bypass valve. O-ring 4) Remove the filter element from the tank. Spring 5) Check the element and the filter case bottom for debris. Excessive amounts of brass and steel particles can indicate a failed hydraulic pump or a pump failure in process. A rubber type of material can indicated cylinder packing or other packing failure.

The hydraulic oil filter in the filter case of the hydraulic oil tank should be replaced every 1000 operating hours or more often. When the filter element is replaced, please keep as follows. By-pass valve Return filter ц (1) Clean the inside of the filter case. (2) Place new element in the proper positions inside the filter case. (3) Install the bypass valve and spring. Make sure the element stand upright, and check for complete contact of the element bottom with the filter case bottom. (4) Install the O-ring and filter case covers. Tighten them with bolt. Replace the O-ring with new one if damaged. 760F6WE24 6-63