. OPERATION OPERATION OPERATION OPERATION key into starting and turn ON 6. When the engine starts, release the key in starting switch (2). The key will return automatically to ON position (B). REMARK Immediately after an engine startup, keep the engine at idle, and while the engine is at idle, keep the foot off the deceleration pedal and do not operate the work equipment. 3 - 113 2. position ( switch (2) the key to 3. Check th at engine pre-heating monitor (3) o n the monitor panel lights up. 4. Maintaint he key in the ON position (B) until engine pre-heating monitor ( 3) goes off. 5.
When en gine pre-heating monitor (3) goes off, tur n the key of starting switch (2) to the S TART position (C) to crank the engine. The time that engine pre-heating monitor (3 ) stays on changes according to th e ambient te mperature as s hown in the tab le below . Ambient temperature Pre-heat time -3°C to -10°C (27°F to 14°F) 5 to 15 seconds -10°C to -20°C (14°F to -4°F) 15 to 32 seconds -20°C to -30°C (-4°F to -22°F) 32 to 45 seconds