Komatsu — EVERY 4000 HOURS SERVICE

. MAINTENANCE SERVICE PROCEDURE REPLACE ACCUMULATOR (FOR CONTROL CIRCUIT) WARNING accumulator. 4 - 88 EVERY 4000 HOURS SER Maintenance f or every 50, 250, 5 00, 1000 and 2000 h ours servic e should be c arried out at the Replac e the a ccumulator every 2 years or every 4 000 hours, whichever comes The acc umulato r is charged with hig h-pressure nitroge n gas , so m istaken operation may cause an explosi on, which will lead to serious injury or damage. When han dling the accumulator, a lways do as f ollows. The pressure in the hydraulic circ uit cannot be completel y removed.

When removing the hydraulic equi pment, do not stand in th e directio n that the oil spurts out when carrying out t he operation. In addition, loo sen the bolts slow ly when carrying out the o peration Do n ot disassemble the accumula Do n ot bring it near flame or dispo Do n ot make holes in it or weld it Do n ot hit it, r oll it, or subject it to Whe n disposi ng of the accumulato r, the gas must be released. C ontact your Komatsu d istributor to have t his work carried out. If operations a re continued whe n the function of accumulator (1) has dr pressu machi If this opped, it becomes impossible to release the remaining re in the hydraulic circuit when there is a failure in the ne.

happens, ask your Komatsu distributor to replace the CHECK WATER PUMP Check the wat er pump and its rel ative parts for water l eak, and if a nything abno rmal is found, cal l on your Komatsu distributor for r epairs or replacem ent. CHECK STARTING MOTOR r to have the starting motor checked. Contac t your K omatsu distributo r to have the starting moto r checked. If t he e ngine is started frequently , have this inspection carried out every 1000 h