D 2011 w Cooling system TD 2011 w, TCD 2011 w W 09-08-01 Checking the thermostat (in the removed state) Commercial available tools: – Thermometer W 09-08-02 Danger! Risk of injury! Hot water and hot thermostat. 6 Checking thermostat z Remove thermostat. W 09-08-02 z Measure beginning of stroke, dimension (a). z Note measured value, dimension (a). © 34679-3 z Heat up the thermostat in the water bath. In order to determine the exact beginning of opening, the temperature should be measured as close as possible to the ther- mostat. The water should be continuously stirred for an even temperature distribution. The temperature rise should not take place faster than 1°C/min.
Otherwise the begin- ning of opening will be delayed accordin- gly. z Determine beginning of opening. 86 - 90 °C © 34680-2 © 12/2008 17836-001 1/4