Deutz — Removing and installing temperature transmitter

D 2011 w Cooling system TD 2011 w, TCD 2011 w W 09-12-01 Technical Data Tightening specifications For the tightening procedure according to torque using a torque wrench, a maximum variation of the tightening torque of +/- 10% is permissible. 6 © 12/2008 17839-001 3/4 D no. Name Screw type Notes / Remark Value A09 031 Temperature transmitter on thermo- stat housing 25 Nm