D 2011 w Other components TD 2011 w, TCD 2011 w W 12-02-01 z Mount V-belt tension measuring device on V-belt. The V-belt must be between the guides (arrow). 6 © 46997-1 z Press the V-belt measuring device against the V-belt with the button (1) until you hear it click. z Read measured value at the intersection (arrow) of the indicator arm and scale. 450 N + 50 50 Note different units on the scale. z If the nominal value is not reached, the tensioning process must be repeated. 1 © 46997-0 z Tighten screws (1). 34 Nm 1 z Tighten screw (2). 22 Nm The V-belt tension of new V-belts must be checked after they have been running for 15 minutes. + 20 20 300 N 2 © 46987-2 © 12/2008 17842-001 4/8