Komatsu — DISCHARGED BATTERY

OPERATION TROUBLESHOOTING REMOVAL AND INSTALLATION OF BATTERY Removal of battery 1. Open the battery right side inspection cover, loosen bolt (1) and then remove rubber cover (2) installed to the top of the battery. 2. Remove cable (3) from the negative (-) terminal (ground). 3. Remove connection cable (4) and cable (5) from the pos- itive (+) terminal. 4. Remove mounting bolts (6), then remove mounting holder (7). 5. Remove the battery to the outside of the machine. Installing battery NOTICE After fixing the battery in position, check that it does not move. If it moves, install it again. 1. Set the battery in the specified position. 2.

Secure the battery in position with mounting holder (7) and mounting bolts (6). Tightening torque for mounting bolts: 4.9 to 5.88 N•m (0.5 to 0.6 kgf•m, 3.6 to 4.3 lbft) 3. Install cable (5) at the positive (+) terminal end. 4. Connect connection cable (4) from the positive (+) terminal end. 5. Connect cable (3) to the negative (-) terminal end (ground). 6. Install rubber cover (2). 3-107