Brakes 42 this may result in contamination and malfunction- ing of downstream air system components. 42–11 Versajust Slack Adjuster Inspection and Lubrication Refer to Fig. 9 for cartridge replacement. 1. Drain the air system. IMPORTANT: Perform the Brake Inspection maintenance operation before lubricating the slack adjusters. 1. Visually check for physical damage, such as bro- ken air lines and broken or missing parts. 2. Using a quality multipurpose chassis lubricant, NLGI Grade 2, lubricate the slack adjuster through the grease fitting until clean lubricant flows from the grease relief opening in the boot. 2 3 3. Perform the "In Service Inspection." In Service Inspection 1 1.
Apply and release the brakes several times while observing the slack adjuster. The slack adjuster and brake actuator should move freely, without binding or interference, and should return to the full released position. Observe the looseness that exists between the clevis and adapter bushing and the yoke and link pins and their mating parts (clevis, body, link). Replace these parts if loose- ness appears excessive. Make certain the brake actuator pushrod jam nut is tightened securely. 08/05/94 f421292 1. Seal 2. O-Ring 3. Air Dryer Base Fig. 9, Desiccant Cartridge Replacement 2. Using a strap wrench, turn the desiccant car- tridge counterclockwise and remove it. 2.
Inspect the slack adjuster for physical damage, paying attention to the link, boot, and clevis. If any components are damaged, repair or replace them as necessary. 3. Remove and discard the O-ring. 4. Clean the top surface of the dryer base with a commercial cleaning solvent. 3. Measure the brake actuator pushrod stroke while making an 80 to 90 psi (552 to 621 kPa) brake application. Actuator pushrod strokes should not exceed the values shown in Table 2 and Table 3 . To achieve the correct pressure for this test, build the system pressure up to a 100 psi (690 kPa). Shut down the engine. Fan the brakes to attain a 90 to 95 psi (621 to 655 kPa) reading.
Make and hold a full brake application while the strokes are checked. IMPORTANT: If the air dryer base is damaged, preventing a tight seal, replace the air dryer. 5. Using a multipurpose, high-temperature grease that resists water, steam, and alkali, lightly coat the surfaces of the new O-ring and the dryer base. Install the O-ring. 6. Thread the desiccant cartridge onto the dryer base (turn clockwise). When the seal contacts the base, tighten the cartridge one complete turn more. Do not overtighten. Actuator Stroke–Standard Stroke Brake Actuator Size Recommended Maximum Operating Stroke (Inches) 30 2 24 1-3/4 Cascadia Maintenance Manual, November 2015 42/11