Freightliner — Cascadia

Fuel 47 7 10 6 8 9 5 4 11 3 2 12 02/04/2014 f470617 1 1. Pressure Control Regulator 2. Vapor Shutoff Valve 3. Fuel Fill Hose 4. Secondary Relief Valve (red cap) 5. Fuel Fill Fitting 6. Fuel Level Sender Box 7. Primary Relief Valve 8. Tank Pressure Gauge 9. Fill Vent Fitting 10. Excess Flow Valve 11. Fuel Shutoff Valve (liquid) 12. Fill Check Valve Fig. 6, LNG Tank Plumbing Components Plumbing Components Inspecting 3. Ensure the red cap is present on the secondary relief valve. See Fig. 6 for plumbing component locations. 4. Inspect the fuel tank pressure gauge for cracks in the sight glass. Ensure the indicator needle is present and in working condition.

Inspect the gauge face for accuracy and legibility. Use a bubble solution to check for leaks while per- forming the following visual inspection. 1. Check the following components for signs of damage or leaks. 5. Inspect all vent lines for kinks, and signs of leaks or damage. 6. Replace leaking or damaged fuel lines. Repair or replace leaking or damaged fittings. Fuel Level Sender Component Inspecting Pressure control regulator Vapor shutoff valve Secondary relief valve Primary relief valve and threaded connec- tions Excess flow valve 1. Inspect the fuel level sender wiring harness for signs of loose connections or damage. Look for cracking or signs of moisture intrusion.

Fuel shutoff valve Fill check valve 2. Inspect the fuel level sender box ( Fig. 6 ) for signs of leaks or damage. Ensure that the re- tainer clips are installed on the mounting ears. 2. Inspect the fuel fill line for signs of damage, kinked or crushed piping, or chafing. Cascadia Maintenance Manual, August 2015 47/6