Exhaust 49 1 10 11 2 9 3 7 4 8 5 6 09/16/2009 f490354 1. DPF Inlet Temperature Sensor 2. DOC Inlet Temperature Sensor 3. DOC Inlet Pressure Sensor 4. DPF Sensor Box 5. DPF Outlet Pressure Sensor 6. DPF Outlet Temperature Sensor 7. DPF Outlet NOx Sensor 8. SCR Inlet Temperature Sensor 9. SCR Outlet Temperature Sensor 10. SCR Sensor Box 11. SCR Outlet NOx Sensor Fig. 3, 2HV Two-Box ATS Sensor Locations Pre-EPA07 Exhaust System 5. Inspect the turbo outlet pipe, and replace it as needed. 1. On all vehicles, check the condition of the muffler body and the top stack. Check the inlet/outlet tubes for leakage, dents, and corrosion, and check for holes in the muffler. Replace parts as required.
Use new parts, equivalent to parts originally installed on the vehicle. 6. Check the U-bolt clamps for tightness, and tighten as needed. 7. Check the isolator at the base of the exhaust stack elbow(s) (see Fig. 7 ), for cracking, dam- age, and dry rot. Replace as needed. 2. Inspect the exhaust flex hose (see Fig. 6 ) for leakage, wear, or damage. Replace with new parts if replacement is needed. 8. Check for leakage at all wide-band exhaust clamps. See Fig. 8 . If leakage exists, tighten the nuts 40 to 60 lbf·ft (54 to 81 N·m). If leakage persists, inspect the sealclamps. If necessary, install a new wide-band exhaust clamp. 3.
Check for leakage at the V-band coupling, which attaches the exhaust pipe to the turbocharger exhaust outlet. See Fig. 6 . 4. If leakage exists, tighten the nut on the V-band coupling 85 lbf·in (940 N·cm). If leakage persists, install a new V-band coupling. Cascadia Maintenance Manual, November 2015 49/5