Engine Cooling/Radiator 20 4. Remove the drain plugs at the radiator side tank and at the lower radiator outlet pipe elbow, if equipped. See Fig. 2 . Allow the coolant to drain. 10. Connect the hoses. Your hose clamps can be either T-bolt clamps (see Fig. 3 ) or Breeze Constant-Torque clamps (see Fig. 4 ). When working with T-bolt hose clamps, tighten the clamps 55 lbf·in (620 N·cm). These clamps are now standard on hoses with an inside diam- eter greater than 2 inches (51 mm). When installing Breeze Constant-Torque hose clamps, the clamps must be tightened to the cor- rect torque.
The screw tip of the clamp must ex- tend about 1/4 inch (6 mm) from the clamp hous- ing, and the Belleville washer stacks must be collapsed almost flat. Use a torque wrench to install these clamps correctly. The correct instal- lation torque is as follows: 1 For Breeze Constant-Torque clamps with a 5/16- inch tightening screw hex: 55 lbf·in (620 N·cm). 1 For Breeze Constant-Torque clamps with a 3/8- inch tightening screw hex: 90 lbf·in (1020 N·cm). 06/29/95 f011008 NOTE: Cummins engine shown. 1. Coolant Drain Plug Fig. 2, Coolant Drain Plug Location 5. Disconnect the radiator upper and lower hoses, and install the surge tank cap and the radiator side-tank drain plug.
Attach the flushing gun nozzle to the radiator at the lower radiator hose opening. Run the water until the radiator is full. CAUTION When flushing the radiator, do not apply more than 15 psi (100 kPa) air pressure. Excessive pres- sure can damage the radiator. 02/28/96 f200326 6. Gradually, apply up to 15 psi (100 kPa) air pres- sure to help dislodge sediment that has built up in the radiator core. Fig. 3, T-Bolt Type Hose Clamp NOTE: All hose clamps will lose torque after installation due to "compression set." However, when correctly installed, Breeze Constant- Torque clamps will hold enough torque to auto- matically adjust and keep consistent sealing pressure.
During vehicle operation and shut- down, the screw tip may adjust according to temperature and pressure changes. The torque may need to be adjusted for individual applica- tions. 7. Shut off the air at the pressure gun nozzle and allow the radiator to refill with water. 8. Repeat the previous two steps until clean water flows from the radiator. 9. Remove the radiator side-tank drain plug and allow the radiator to drain. Install and tighten the side-tank drain plug and the radiator outlet pipe drain plug after the radiator has been drained. Do not overtighten the plugs. 11. Place a pan under the coolant filter to catch en- gine coolant. Cascadia Maintenance Manual, August 2015 20/2