Freightliner — Cascadia

Rear Axle 35 4.2 Wash the strainer in solvent, and blow it dry with compressed air to remove oil and metal particles. 1 4.3 Install and tighten the magnetic strainer 40 to 60 lbf·ft (54 to 81 N·m). 5. Clean the fill and drain plugs. Change them if necessary. 5.1 For magnetic plugs, use a piece of key stock or any other convenient steel slug to short the two magnetic poles and divert the magnetic field. 2 5.2 Clean away the collected material depos- ited on each pole. Magnets will rapidly lose their effectiveness as collected mate- rial bridges the gap between the two poles. f350018a 05/27/93 1. Oil Fill Plug 2.

Oil Drain Plug 5.3 After the first oil is changed, inspect the drain plug each time for large quantities of metal particles. Fig. 4, Axle Housing Drain and Fill Plugs 5.4 After cleaning, install the drain plug(s) and tighten to 40 to 60 lbf·ft (54 to 81 N·m). 6. Fill the axle with the recommended lubricant. See Table 5 for recommended drive axle lubri- cants, and Table 6 for drive axle lubricant ca- pacities.

Dana Spicer Drive Axle Recommended Lubricant Lubricant Type Condition Lubricant SAE Viscosity Grade 2 Dana Spicer Roadranger® Synthetic Drive Axle Lubricants, or Equivalent with Military Specification MIL–L–2105D Over-the-Road Service 75W–90 1 Off-Highway Equipment, or Under Extra Heavy Loads 80W–140 05/27/93 1. Magnetic Strainer 2. Power Divider f350017a Fig. 5, Dana Spicer Tandem Drive Axle Magnetic Strainer Table 5, Dana Spicer Drive Axle Recommended Lubricant WARNING Dana Spicer Drive Axle Lubricant Capacities Always wear eye protection when using com- pressed air to clean parts, as flying debris could cause permanent damage to unprotected eyes.

Do not point the air stream in the direction of other persons. Axle Type Axle Model Capacity: * Pints (liters) Single Drive Axle Installation Cascadia Maintenance Manual, August 2015 35/5