108 Operation Section (D6T LGP (OEM)) WEBM1000 Towing Information 142 143 Illustration 142 (1) FT1973 Adapter Gp (2) 8T-0855 Pressure Gauge (3) 8T-0477 Relief Valve (4) Handle (5) 6V-5016 Ball Valve (6) FT1845 Brake Release Pump (7) 123-0525 Brake Release Adapter (Not shown) 5P-2909 Plug Illustration 143 1. The main pressure hose connects to 9J-6190 Adapter Union, 04-6683 Nipple, 5P-8018 Adapter Union, 8M-0547 Elbow, and 5P-2909 Plug. Plug the pressure hose at the connection with a 5P-2909 Plug. The components are indicated by shaded area (A). The machine brakes can be released for towing. Use FT1973 Adapter Gp (1), two 123-0525 Adapters (7), and FT1845 Brake Release Pump (6). 2.
Turn the handle of bypass valve (5) to the closed position. 3. While you are pumping handle (4), observe the opening pressure of relief valve (3). Relief Valve Setting NOTICE Possible brake piston seal damage could result without checking relief valve. Opening pressure must be checked and adjusted before connection is made. 4. Adjust the opening pressure of the relief valve. Set the pressure to 3030 70 kPa (440 10 psi). 5. Turn the handle on bypass valve (5) to the open position in order to relieve the pressure in the pump and in the hose.