139 WEBM1000 Maintenance Section (D6T LGP (OEM)) Engine Oil Sample - Obtain Engine Oil Sample - Obtain 4. Replace the protective cap. 5. Close the engine access door. m WARNING Refer to Operation and Maintenance Manual, “Lubricant Viscosities” for the correct fluid for your machine. Hot oil and components can cause personal injury. Do not allow hot oil or components to contact skin. Engine Oil and Filter - Change NOTICE Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product.
Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Selection of the Oil Change Interval NOTICE A 500 hour engine oil change interval is available, provided that the operating conditions and recommended multigrade oil types are met. When these requirements are not met, shorten the oil change interval to 250 hours, or use an S·O·S Services oil sampling and analysis program to determine an acceptable oil change interval. Refer to Special Publication, NENG2500 “Caterpillar Dealer Service Tool Catalog” for tools and supplies suitable to collect and contain fluids on Caterpillar products.
If you select an interval for oil and filter change that is too long, you may damage the engine. Dispose of all fluids according to local regulations and mandates. Cat oil filters are recommended. Obtain the sample of the engine oil as close as possible to the recommended sampling interval. The recommended sampling interval is every 250 service hours. In order to receive the full effect of S·O·S oil analysis, you must establish a consistent trend of data. In order to establish a pertinent history of data, perform consistent oil samplings that are evenly spaced.
Refer to this Operation and Maintenance Manual, “Lubricant Viscosities” for further information about oils that may be used in Cat engines. Refer to this Operation and Maintenance Manual, “Severe Service Application ” to determine if oil change interval should be reduced from the normal change interval. If operating in any of the conditions or environments outlined in the Severe Service Application, use S·O·S Services oil analysis to determine the best oil change interval. If S·O·S Services oil analysis S is not being used, oil change interval should be reduced to 250 hrs. 1. Open the engine access door on the right side of the machine. 174 Illustration 174 2. Remove the protective cap. 3.
Use 169-8373 Fluid Sampling Bottle in order to obtain a sample of the engine oil.