164 Maintenance Section (D6T LGP (OEM)) WEBM1000 Refrigerant Dryer - Replace Refrigerant Dryer - Replace (If Equipped) 228 m WARNING Personal injury can result from contact with refrigerant. Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury. Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant. Always use precaution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area. Personal injury or death can result from inhaling refrigerant through a lit cigarette.
Illustration 228 Location of the refrigerant dryer is behind the lower access door Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death. on the left side of the machine. 229 Do not smoke when servicing air conditioners or wherever refrigerant gas may be present. Use a certified recovery and recycling cart to properly remove the refrigerant from the air conditioning system. Note: The refrigerant dryer contains the orifice tube and the desiccant that dries the liquid refrigerant.
Illustration 229 This refrigerant dryer does not have quick couplers. Reference: For the correct replacement procedure, refer to Service Manual, SENR5664, “Air Conditioning and Heating R-134a All Caterpillar Machines”“In-Line Refrigerant Dryer - Remove and Install” or the Disassembly and Assembly Manual, for your machine.