174 Maintenance Section (D6T LGP (OEM)) WEBM1000 Transmission System Oil Sample - Obtain 255 Obtain the sample of the transmission oil as close as possible to the recommended sampling interval. The recommended sampling interval is every 500 service hours. In order to receive the full effect of S·O·S oil analysis, establish a consistent trend of data. In order to establish a pertinent history of data, perform consistent oil samplings that are evenly spaced. If the machine is operated under high load and/or under high temperature conditions, sample all fluids at the 250 hour interval. 256 Illustration 255 1. Remove the cover from the rear of the transmission.
The scavenge screen is located behind the cover. 2. Wash the screen in a clean, nonflammable solvent. 3. Inspect the seal. If the seal is damaged, replace the seal. 4. Install the screen and the cover. Transmission System Oil Sample - Obtain Illustration 256 The oil sampling valve for the power train is shown. 1. Open the access cover on the right side of the cab in front of the hydraulic tank. m WARNING Hot oil and components can cause personal injury. 2. Remove the protective cap. 3. Use 8T-9190 Fluid Sampling Bottle (1) to obtain a sample. Do not allow hot oil or components to contact skin. 4. After you take a sample, remove the cap with the probe from the bottle.
Discard the cap with the probe. Install the sealing cap that is provided with 8T-9190 Fluid Sampling Bottle (1). NOTICE Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting, and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. 5. Replace the protective cap. 6. Install the access cover. Refer to Special Publication, NENG2500 “Dealer Service Tool Catalog” for tools and supplies suitable to collect and contain fluids on Cat products. Reference:
Refer to , “Lubricant Viscosities” in the Maintenance Section of this manual for the correct fluid for your machine. Dispose of all fluids according to local regulations and mandates. Window Washer Reservoir - Fill NOTICE When operating in freezing temperatures, use Caterpillar or any commercially available nonfreezing window washer solvent.