214 Maintenance and Lubrication Section (Pipelayer Attachment Kit) WEBM1000 Boom Stop Valve Operation and Adjustment Table 33 Raise the boom vertical so that it is JUST in contact with the tower; the boom kick-out rod is fully retracted into the tower. Do not over tighten the lines to the point that the boom or structures are overly stressed. Remove the boom stop valve access panel from the tower. Loosen the boom stop valve nuts. Move the valve so that it just contacts the boom kick-out rod. Move the valve an additional 10 mm (3/8-in) towards the boom so that the valve's piston is fully depressed. Tighten the valve in position with the valve nuts.

Test the boom stop valve to see that it works properly. Lower the boom until the boom stop valve piston is free from the kick-out rod. Boom Stop Valve Operation and Adjustment Replace the boom stop valve access panel from the tower. m WARNING Boom in slowly taking care not to over tension the boom lines when the boom goes vertical. When the boom is vertical, the kick-out rod will move the boom stop valve piston in 9.5 mm (3/8 in), and the boom winch should stop with the boom vertical. No increase in tension should occur once the boom comes into contact with the left hand tower, readjust the boom stop valve as required.

The Boom Stop system stops the boom winch from hauling-in when the boom is vertical, preventing overloading of key machine components. Incorrectly adjusting, or defeating the boom stop valve could result in serious equipment damage, personal injury, or even death. Its operation must be check and verified daily. Boom Line – Install m WARNING 284 Do not operate or work on this equipment unless you have read and understand the instructions and warnings in the Operation and Maintenance Manual. Failure to follow the instructions or heed the warnings could result in injury or death. Contact your dealer or Vanguard Equipment or visit our website at vanguardequip.com for replacement manuals.

Proper care is your responsibility. Illustration 284 Boom stop valve located behind access cover in Left Hand tower. To check the operation, boom in slowly taking care not to over tension the boom lines when the boom goes vertical. When the boom is vertical, the boom winch should stop. No increase in tension should occur once the boom comes into contact with the left hand tower. If the boom winch does not stop and continues to increase the cable tension, STOP the operation at once and lower the boom to release the tension. Adjust the boom stop valve as set out below. m WARNING Personal injury or death can result from worn wire rope cable. Worn or frayed cable could break causing injury.

Check the wire rope cable. If cable is worn or is frayed install new cable. Wear gloves when handling the wire rope cable. Proper care is your responsibility. Ambient air temperature [°C (°F)] Accumulator precharge pressure [kPa (psi)± 70 kPa (10 psi) -7°C (20°F) 3100 kPa (450 psi) -1°C (30°F) 3170 kPa (460 psi) 4°C (40°F) 3240 kPa( 470 psi) 10°C (50°F) 3310 kPa (480 psi) 16°C (60°F) 3375 kPa (490 psi) 21°C (70°F) 3445 kPa (500 psi) 27°C (80°F) 3515 kPa (510 psi) 32°C (90°F) 3580 kPa (520 psi) 38°C (100°F) 3650 kPa (530 psi) 43°C (110°F) 3720 kPa (540 psi) 49°C (120°F) 3790 kPa (550 psi)