Cooling System/Fan Belt Tension Specifications COMPLETE FINAL ASSEMBLY NOTE: Consult your engine operator’s manual or see Group 02 of this CTM for coolant recommendations in your area. 1. Fill cooling system to proper level with the proper coolant. 2. Start engine and run for several minutes to check for leaks in the cooling system. 3. After fan belts cool, check belt tension as detailed in your operator’s manual. RG,CTM42,G25,31-19-15SEP94 FAN BELT TENSION SPECIFICATIONS • JDG529 Gauge Method (Standard V-belts) JT05975 Gauge Method (Poly V-belts): FAN BELT TENSION SPECIFICATIONS (Using JDG529 or JT05975 Tension Gauge Method) New Belt Belt in Service* Standard V-Belts:
Single Belt System 578—623 N 378—423 N (130—140 lb) (85—95 lb) 2-Belt System 423—463 N 378—423 N (Tension Front Belt (95—104 lb) (85—95 lb) Only) Poly V-Belts: Single Belt System 890—1068 N 801—979 N (200—240 lb) (180—220 lb) 25 26 • JDST28 Belt Tension Gauge/Straightedge Method: —On new and used standard V-belts, an 89 N (20 lb) force halfway between the pulleys should deflect the belt 19 mm (3/4 in.). —On new and used poly V-belts, a 130 N (30 lb) force halfway between the pulleys should deflect the belt 13 mm (1/2 in.). *Belts are considered used after 10 minutes of operation. CTM42 (24MAR95) 25-26 6076 Diesel Engines—S.N. (500000— ) RG,CTM42,G25,39-19-01SEP94 160101 PN=245