John Deere 400 6076 — John Deere 400 6076 User Manual

Fuel System/Remove and Install Fuel Shutoff Solenoid REMOVE AND INSTALL FUEL SHUTOFF SOLENOID RG5968 -UN-11SEP91 A—Wiring Connector D—Cotter Pin G—Lock Washer and Screws J—Solenoid Mounting B—Fuel Shutoff Solenoid E—Washer H—Hex Nuts Bracket C—Solenoid Shaft F—Fuel Shutoff Lever I—Cap Screws 1. Disconnect electrical wiring connector (A) in solenoid lead. IMPORTANT: Fuel shutoff solenoid linkage should move freely back and forth. On “A” pumps if linkage is binding, check pump for proper alignment. (See INSTALL IN-LINE “A” AND “P” FUEL INJECTION PUMPS, later in this group.) 2. Remove cotter pin (D), washer (E), and pull solenoid shaft (C) out of fuel shutoff lever (F). 3.

Remove fuel shutoff solenoid (B) from solenoid mounting bracket (J) by removing hex nuts (H), lock washers, and machine screws (G). NOTE: Electric fuel shutoff solenoids are factory adjusted to a specified length and should not require additional adjustment. See machine technical manual for fuel shutoff solenoid diagnostics. 4. If solenoid mounting bracket is to be removed, remove cap screws (I) and lock washers that fasten the bracket to oil filter housing. 5. To install fuel shutoff solenoid, reverse removal procedure. Tighten cap screws (I) to 23 N·m (17 lb-ft) and hex nuts (H) to 7 N·m (5 lb-ft). 35 24 CTM42 (24MAR95) 35-24 6076 Diesel Engines—S.N.

(500000— ) RG,CTM42,G35,77-19-16AUG94 160101 PN=301