Fuel System Operation and Test/Check and Adjust Engine Speeds on Rotary Pump CHECK AND ADJUST ENGINE SPEEDS ON ROTARY PUMP—STANADYNE DB4 115 41 RG6485 -UN-26OCT92 A—Fast Idle Adjusting Screw B—Slow Idle Adjusting Screw NOTE: Before adjusting engine speed, make sure engine has reached its normal operating temperature. Adjust slow idle speed if necessary as detailed below. 5. Move throttle lever to the fast idle position against adjusting screw stop. Check Slow and Fast Idle Speeds: 6. Read and record engine speed using a tachometer. Compare readings with specifications. 1. Start engine and run at 50% load and rated speed until engine reaches normal operating temperature. IMPORTANT:

If fast idle is not within specification, have an authorized diesel repair station, servicing dealer, or engine distributor adjust as necessary. 2. Stop engine and disconnect speed control rod or cable from injection pump throttle lever. 3. Start engine and run at slow idle and no-load until engine stabilizes. Move injection pump throttle lever to slow idle position against adjusting screw stop. Adjust Slow Idle Speed: 4. Measure engine speed using a tachometer. Compare reading with specification. 1. Hold pump throttle lever against slow idle stop. 2. Loosen slow idle adjusting screw lock nut. Turn adjusting screw clockwise to increase speed and counterclockwise to decrease speed.

RG,CTM42,115,32-19-14FEB95 CTM42 (24MAR95) 115-41 6076 Diesel Engines—S.N. (500000— ) 160101 PN=424