Komatsu — 10.3.1 CHECKS BEFORE STARTING

OPERATION 10. HANDLING RADIO CONTROL If the base machine or operator are in danger, do as follows. Emergency stop When this switch is pressed, the engine stops and all output matching the operation of the levers is also stopped. (The hydraulic pressure of the valve unit is blocked, and all operations, including the horn, become ineffective.) The parking brake is applied. To start the engine again, pull the emergency stop switch, turn all the transmitter switches OFF, set the engine speed to idling, and return all levers to neutral. Check that the situation is safe, then start the engine. Key switch OFF The power supply for the transmitter is turned OFF, and the engine stops after approx.

3 seconds. 3-23 Item Engine All valves Emergency stop Stops Stops Transmitter power OFF Stops Stops Tilt stop Stops Stops Reception error Stops Stops Lack of battery capacity Stops Stops