15. IF ANY FAILURE IS SUSPECTED OPERATION 15. IF ANY FAILURE IS SUSPECTED 15.1 RADIO CONTROL OPERATION 15.2 ON-BOARD OPERATION (ONLY PROBLEMS RELATED TO RADIO CONTROL) 15.3 REPORTING FAILURE If any failure occurs on the basic machine or radio control unit, please inform the machine serial No., engine serial No., and the service meter reading. The machine serial No. and engine serial No. are given on the service warranty and nameplate. See the explanation of the components for details of the service meter.
3-32 Problem Probable cause Remedy Transmitter pilot lamp does not flash ● Dead battery ● Install charged battery Engine does not start ● Transmitter key switch is not turned ● Emergency stop switch has not been canceled ● Parking lever is not released (raised) ● Drop in battery voltage ● Turn to position 1 ● Pull switch to cancel ● Release lever (raise) ● Charge or replace battery Work equipment does not move, machine does not travel ● Transmitter key switch not turned to 2nd stage ● Turn to START position (hold in position for approx.
1 sec.) Engine suddenly stopped ● Engine has run out of fuel ● Dead battery ● Reception error ● Radio control/on-board switch has changed to ON-BOARD ● Disconnected, damaged elec- trical relay ● Add fuel ● Install charged battery ● Check location of interference ● Check radio wave distance ● Check around selector switch ● Install, replace relay Problem Probable cause Remedy Engine suddenly stopped ● Radio control/on-board switch has changed to ON-BOARD ● Check around selector switch