eng — 24.5 EVERY 250 HOURS SERVICE

24. SERVICE PROCEDURE 24.5.2 CHECK CHECK Push the FAN BELT TENSION, intermediate point ADJUST between the (EG125B-2) alternator and fan pulley with the thumb (About 59 N (6 kgf, 13.2 Ibft)). It should be deflected 10 mm (0.4 in). ADJUSTMENT 1. To adjust the belt tension, loosen bolt @ and nut @ and shift alternator @) slightly. When adjusting the V-belt, do not attempt to push alternator @ directly with a bar or the like, but use a wood pad to prevent damage to the core. 2. Check each pulley for damage and V-grooves and AB716700 Fan pulley V-belt for Approx. 10mm (0. 4 in) Alternator pulley wear. Particularly, check to see if the V-belt touches the bottom of any V-groove. 3.

If the belt is lengthened eliminate the adjustment allowance or it has any cut or crack, replace it. Crank pulley ADTI671B / - AB716720 24.5.3 CHECK INSULATION RESISTANCE Remove the electric wire at the load end of the output terminal board, turn the breaker ON, and measure the insulation between the hood and the output terminal bolt. resistance If the measurement is less than 1 MQ, there is danger of electric shock or fire, so carry out repairs. 24.5.4 CHECK GREASE OF SHAFT BEARING 1. Remove bearing cover, check for dirt, and check that the grease chamber is about 1/3 full. 2. if the grease level is low, add the same type of grease. If the grease is very dirty, change the grease.

A8716730 3-37