eng — 16.2 IF BATTERY IS DISCHARGED

16. TROUBLESHOOTING 16.2.1 REMOVING AND INSTALLING BATTERY When removing (from the terminal the negative and the battery, © disconnect terminal machine body side, the grounded in general) is connected by a first. tool, cable If the etc., dangerous sparks will be made. When installing the battery, connect the grounded cable at last. After the battery is replaced, secure it with battery fitting. Tightening torque of mounting nut 9.81 — 14.7 Nem (1 — 1.5 kgfem, 7.2 - 10.8 Ibft) NOTICE Secure the battery, and moves, secure it again. confirm that it does not move.

If it Charging battery while still mounted on machine There is danger that an abnormal voltage may be applied to the alternator and damage it, so remove the wires from the battery terminals when charging. Remove all the battery filler caps when charging to release the gas that is generated. lf the battery overheats (the electrolyte exceeds 45°C), stop the charging temporarily. After completing charging, stop the charging immediately. If charging is continued after the charging is completed, the following problems will occur. 1) Overheating 2) Reduction in battery electrolyte level of battery 3) Problems with battery When connecting the battery, be sure to connect the wires properly.

Never connect (@ to © or © to @). Connecting the wires wrongly will cause damage to the alternator and other parts. Except when checking the battery electrolyte level or measuring the specific gravity, always remove the cables connected to the battery before handling the battery. 2-52