20. USE OF FUEL, COOLANT AND LUBRICANTS ACCORDING TO AMBIENT TEMPERATURE METHOD e OF HANDLING Properties of heavy When WHEN HEAVY OIL A IS USED AS FUEL oil A using heavy oil A as the fuel, use an oil that fulfills the following properties. Specific gravity Flash point Dynamic viscosity 10% residual oil, residual carbon Sulfur content Setane value 15/4°C °C 50°Ccst % % - 0.82 — 0.86 Min. 60 2.0 — 3.5 Max. Max. 0.8 Min. 45 because of the difference in 1.0 e Storage of heavy oil A 1) The moisture, dirt, and sediment in heavy oil A will sink to the bottom specific gravity. Therefore, when taking the oil from a drum can or storage tank, take from the top, and drain the sediment.
2) Always keep the fuel tank full. This can prevent moisture from forming on the inside wall of the tank (condensation), which will prevent moisture from entering the oil. if the sulfur content of the fuel exceeds 0.5%, always carry out analysis of the oil being used (new oil), and determine the oil change interval from the chart below. and Qil change sulfur sulfur TBN not 0.8 fuel 1/2 0.5 of standard change interval Standard in Proportion of Do of fuel: use a change interval L i 5 15 Total Note: content interval basic number- maKOH/9 20 AD721148 The total basic number (TBN) of class CE and CF-4 oil is low, so it may be impossible to use it together with high sulfur content fuel.
We recommend that you check the sulfur content of the fuel and the TBN of the new oil before starting and follow the chart above to determine the use. 3-11