. ATTACHMENTS, OPTIONS HANDLING PAYLOAD METER II (CARD TYPE) No. Remarks 1 -20% to 20% (Turn to left) - (Turn to right) 2 0: 107 % to 7: 100 % to F: 92 % 3 0: 107 % to 7: 100 % to F: 92 % 4 Refer to model selection chart 5 Up: not used; Down: used 6 Up: not used; Down: used 7 Up: metric tons; Down: short tons 8 Up: permitted Down: prohibited According to permitted/prohibited setting table for switches B For MIN volume, turn to RIGHT For MAX volume, turn to LEFT The switches on the left side are set when the machine is shipped from the factory. Do not touch any switch except "7" and "B".
If you wish to adjust any switch except "7" and "B" to compensate the payload calculation value or speed or distance calculation value, please contact your Komatsu distributor. REMARK The weight is given in units of metric tons or short tons. The meaning of these units is as follows. Metric ton:Unit for the metric system; one metric ton is 1000 kg Short ton:
Unit used in USA:1 short ton is 907.18 kg 6 - 40 DETAILS OF SWITCHES ON LEFT SIDE Name Type Payload gain adjustment trimmer Rotary volume Speed regulation switch 0 - F Rotary switch Distant regulation switch 0 - F Rotary switch Model selection switch 0 - F Rotary switch Use of memory-card switch 2-Stage selector switch Use of clinometer switch 2-Stage selector switch Mass unit setting switch 2-Stage selector switch Forced prohibition setting for switches 2-Stage selector switch Buzzer volume regulation Rotary volume