Komatsu — DETAILS OF DATA STORED IN MEMORY OF PAYLOAD METER

. ATTACHMENTS, OPTIONS HANDLING PAYLOAD METER II (CARD TYPE) ENGINE ON/OFF DATA (MT: Metric Ton; ST: Short Ton) *1: Every time starting switch ON position, the engine operation No. advances by one, and is recorded. The engine operation No. in the cycle data and the engine operation No. in the problem/warning data, which are recorded from the time the engine is switched ON to the time it is switched OFF, are all recorded as an equal value. As a result, when using a personal computer later to compile the data, it is possible to determine what time during the engine operation the cycle data or system problem refers to.

6 - 51 When the engine is started or stopped, these data are recorded in memory. The maximum limit for engine ON/OFF data i s 115 sets of ON/OFF. Item Unit Range Engine operation No. Year (last 2 digits) Month Day Time Hour Time Min Integer Year Month Day Hour Minute 1 - 65535 0 - 99 1 - 12 1 - 31 0 - 23 0 - 59 Consecutive numbers for engine operation (*1) Shows when engine was switched ON Year (last 2 digits) Month Day Time Hour Time Min Year Month Day Hour Minute 0 - 99 1 - 12 1 - 31 0 - 23 0 - 59 Shows when engine was switched OFF Total payload Overall number of cycles MT or ST Times 0 - 9999000 0 - 9999 Total payload from time engine was switched ON to time engine was switched OFF