16.

TROUBLESHOOTING 16.3.3 ENGINE Engine oil pressure warning lamp remains alight when engine speed is raised after completion of warm-up Problem l Engine oil pan oil level is low Main causes Remedy l Clogged oil filter cartridge (sucking in air) l Add oil to specified level, see CHECK BEFORE STARTING l Replace cartridge, see EVERY 250 HOURS SERVICE l Defective tightening of oil pipe joint, oil leakage from damaged (o Check, repair) part l Defective caution lamp (o Replace lamp) Steam is emitted from top part of radiator (pressure valve) Cooling water level low, water leakage Loose fan belt Add cooling water, repair, see CHECK BEFORE STARTING Adjust fan belt tension, see EVERY 1000 HOURS SERVICE Dirt or scale accumulated in cooling system Clogged radiator fin or damaged fin Change cooling water, clean inside of cooling system, see WHEN REQUIRED Clean or repair, see EVERY 500 HOURS SERVICE Replace thermostat) Tighten cap or replace packing Defective thermostat Loose radiator filler cap (high altitude operation) Defective water temperature Indicator of water temperature gauge is in red range on right side of gauge gauge Replace water temperature gauge) Indicator of water temperature gauge is in white range on left side of gauge l Defective thermostat (e Replace thermostat) (e Replace water temperature gauge) l Defective water temperature gauge Engine does not start when starting motor is turned Lack of fuel l Add fuel, see CHECK BEFORE STARTING Air in fuel system l Repair place where air is sucked in (0 Replace pump or nozzle) 1 See ELECTRICAL SYSTEM Starting motor cranks engine sluggishly Defective fuel injection pump or nozzle Heater signal does not glow red Defective compression o Defective valve clearance 10 Adjust valve clearance) Exhaust gas is white or blue l Too much oil in oil pan l Add oil to specified level, see CHECK BEFORE STARTING l Improper fuel l Change to specified fuel Exhaust gas occasionally turns black l Clogged air cleaner element l Clean or replace, see WHEN REQUIRED l Defective nozzle l Defective compression (o Replace nozzle) (o Adjust valve clearance) Combustion noise occasionally makes breathing sound l Defective nozzle (o Replace nozzle) Abnormal noise generated (combustion or mechanical) l Low grade fuel being used l Change to specified fuel l Overheating l See item “Indicator of water temperature gauge is in red range on right side of gauge”.

l Damage inside muffler s Excessive valve clearance (o Replace muffler) (e Adjust valve clearance) 2-61