Komatsu — 24.2 WHEN REQUIRED

24. SERVICE PROCEDURE l When deciding the ratio of antifreeze to water, check the lowest temperature in the past, and decide from the mixing rate table given below. It is actually better to estimate a temperature about 10°C (50°F) lower when deciding the mixing rate. Mixing rate of water and antifreeze Min. atmospheric temperature -5 -10 -15 -20 -25 -30 23 14 5 -4 -13 -22 A WARNING Antifreeze is flammable, so keep it away from any flame. l Use city water for the cooling water. If river water, well water or other such water supply must be used, contact your Komatsu distributor. l We recommend use of an antifreeze density gauge to control the mixing proportions.

A WARNING When removing drain plug, avoid pouring coolant on yourself. 3-21