Komatsu — 24.2 WHEN REQUIRED

24. SERVICE PROCEDURE 24.2.2 CHECK, CLEAN AND REPLACE AIR CLEANER ELEMENT 7 g WARNING I l Do not clean or replace the air cleaner while the engine is running. l When cleaning the element with compressed air, wear pro- tective goggles to protect your eyes from dust. Checking If air cleaner caution lamp E:, lights up, clean the outer element r of the air cleaner. Cleaning or replacing outer element 1. Remove hood catcher @ on the left side. A0217360 2. Remove wing nut 0, then remove the outer element. 3. Clean the inside of the body. 4. Blow dry compressed air (0.69 MPa {7kg/cm2} maximum) against the inside of the element along the pleats.

Then, blow against the outside along the pleats, then against the inside again. Remove one seal each time the element is cleaned. After cleaning the outer element six times or using it for one year, replace it. At this time, replace the inner element, too. Even if the number of cleaning times of the outer element is ADO53020 (I) (2) (3) up soon after it is cleaned, replace both outer and inner elements. less than six, if the air cleaner clogging caution lamp lights / / (4) Check the clamping nut of the inner element for looseness, and tighten it if necessary. If seal washer @I is damaged or the threads of wing nut @ are broken, replace them with new ones.

Remove evacuator valve 0 and clean it with compressed air, etc., :hen install it again. AE218740 (5) (6) 3-25