24. SERVICE PROCEDURE 0 Manual air bleeding procedure 1. After replacing filter cartridge 0, loosen air bleed plug 0. 2. Loosen the knob @ of feed pump and move it up and down (several tens of strokes) until bubbles in the fuel flowing out of the air bleed plug are eliminated. 3. Tighten air bleed plug 0. Use Komatsu’s genuine filter cartridge. After replacing the filter cartridge, start the engine and check the filter seal for oil leakage. REMARK When the fuel tank is filled after fuel has run out, bleed air by operating the feed pump as explained above.
l Use of automatic air bleeder (Option) Medium spe WARNING Since the engine starts for bleeding air, confirm safety around the engine thoroughly before cranking the engine. g Air in the fuel circuit can be bled by simply turning on the starting motor with the starting switch according to the following procedure. 1. After replacing the filter cartridge, set the fuel control lever to the medium speed position. 2. Set the safety lock lever of the steering, directional and speed lever to the lock position. 3. Turn the starting switch key to the START position and hold it for 20 seconds.
At this time, the starting motor operates about 2 seconds, then stops, but the air bleeding motor pump keeps operating to bleed air. Hold the key at the START position for 20 seconds, even if the engine starts or not. ti& o:F \ 4. Return the starting switch key to the ON position, and wait for about 30 seconds. 5. Turn the starting key switch to the START position again, and hold it for 20 seconds. At this time, the starting motor operates Y 5 AM090350 about 2 seconds, then stops again. Hold the key at the START position for 20 seconds, even if the engine starts. If it is held at the START position, the motor pump operates to bleed air.
NOTICE Even if the engine starts, hold the starting switch key to the START position for 20 seconds. While it is held, air is bled. If the key is returned to the ON position when the engine starts, air bleeding cannot be completed. 3-48