162.1 REMOVE AND INSTALL BAlTERY l When removing the battery, disconnect the grounding cable (0 terminal side, normally) first. If a tool, etc. touch the terminal and the machine body, sparks are made, which is dangerous. l When installing the battery, connect the grounding cable at last. l When replacing the battery, secure it with battery fitting 0. v AE216660 Tightening torque of mounting nut @ Nut and fitting I Double nut 3.92 - 5.88 N.m (0.4 - 0.6 kgf.m) 34 - 74 N.m (3.5 - 7.5 kgf.mI ‘NOTICE Secure the battery and confirm that it does not move. If there is any movement, secure it again.
16.22 PRECAUTIONS FOR CHARGING BATTERY When charging the battery without removing it from the ma- chine Before charging, disconnect the wiring of the battery terminals, since abnormal voltage may be applied to the alternator to break it. Keep all battery caps removed to release the produced gas while charging. If the battery is overheated (the battery fluid temperature ex- ceeds 45”C), stop charging for a while. After the battery is charged fully, stop charging immediately. Overcharging can cause the following problems.
1) Overheating of battery 2) Reduction of battery fluid 3) Battery trouble Do not connect the cables to the battery inversely (connect the @ cable to the @ terminal, and the 0 cable to the @ terminal). If they are connected so, the alternator, etc. may be broken. When handling the battery for a purpose other than check of the battery fluid level or measurement of specific gravity of the battery fluid, disconnect the cables from it. 2-56