Komatsu — WHEN REQUIRED

WHEN REQUIRED a. CLEAN INSIDE OF COOLING SYSTEM Clean the inside of the cooling system, change the coolant, and add the corrosion resistor agent KI, according to the table. Stop the machine on level ground when cleaning or changing the coolant. Use a permanent type of antifreeze. If, for some reason, it is impossible to use permanent type antifreeze, use an antifreeze containing ethylene glycol. Be sure to replace the corrosion resistor cartridge. Use city water for the cooling water. If river water, well water or other such water supply must be used, con- tact your Komatsu distributor. A Antifreeze is flammable, so keep it away from any flame.

Kind of coolant Cleaning inside of cooling system and changing coolant Replacing corrosion resistor Permanent type antifreeze Every year (autumn) or (All season type) every 2000 hours whichever comes first Non permanent type Every 6 months (spring, antifreeze containing autumn) ethylene glycol (Drain antifreeze in spring, (Winter, one season type) add antifreeze in autumn) Every 1000 hours and when cleaning the inside of the cooling system and when changing coolant Every 6 months or When not using antifreeze every 1000 hours whichever comes first Add antifreeze in the cooling water When deciding the ratio of antifreeze to water, check the lowest tempera- ture in the past, and decide from the mixing rate table given below.

It is actually better to estimate a temperature about 10°C lower when deciding the mixing rate. - 146-