* Measure specific gravity of fluid and obtain rate of charge from the fol- lowing conversion table: Temp. of fluid Rate of 20°C O'C -1oT -20x charm 100% 1.28 1.29 1.30 1.31 90% 1.26 1.27 1.28 1.29 80% 1.24 1.25 1.26 1.27 75% 1.23 1.24 1.25 1.26 * When electrolyte level is low, add distilled water in the morning before ing at night. A To avoid gas explosions, do not bring fire or sparks near the battery. A If the electrolyte gets on your skin or clothes, immediately wash with work instead of after the day”s work. This is to prevent fluid from freez- plenty of clean water. - 93 -