B: AUTOMATIC WARMING-UP OPERATION (STARTING IN COLD AREAS) After starting the engine in cold areas, carry out automatic warming-up operation. 1. Set fuel control dial (I) to the low idling (MIN) position. * After starting the engine, if the engine water temperature is low (below 30”(I), warming-up operation will be carried out automatically. * The automatic warming-up operation is canceled when the engine water temperature reaches the specified temperature (30°C) or after warming-up operation has been continued for 10 minutes, so if the engine water tem- perature and hydraulic oil temperature are still low after the automatic warming-up operation, warm up the engine as follows. 2.
Leave fuel control dial (1) at the low idling (MIN) position and run for ap- prox. 5 minutes under no load. 3. Press working mode switch (2) on the monitor panel to set to H.0 (heavy-duty operation) mode. 4. Turn fuel control dial (1) to the mid-range speed position. (a): Mid-range speed 5. Operate bucket control lever (3) and arm control lever (4) slowly to move the bucket cylinder and arm cylinder to the end of their stroke. (a): In (c): Curl (b): Out (d): Dump 6. Operate the bucket for 30 seconds and the arm for 30 seconds in turn fully for 5 minutes. * When pulling in the work equipment, be careful not to hit the chassis or ground.
* Turn the swing lock switch ON (ACTUATED) and operate the lever to make the oil temperature rise more quickly. 7. Turn fuel control dial (1) to the full speed (MAX) position and carry out the operation in Step 6 for 3 - 5 minutes. (a): Full speed 8. Repeat the following operation 3 - 5 times and operate slowly. l Boom operation RAISE * LOWER l Arm control operation IN f+ OUT 0 Bucket control operation CURL * DUMP 0 Swing operation LEFT ++ RIGHT l Travel (Lo) operation FORWARD t-t REVERSE * If the above operation is not carried out, there may be a delay in re- sponse when starting or stopping each actuator. 9. Use working mode switch (2) on the monitor panel to select the opera- tion mode.
- 96 -