Komatsu — Clean, Replace Air Cleaner Element

MAINTENANCE When Required Clean, Replace Air Cleaner Element If inspection, cleaning, or maintenance is carried out with the engine running, dirt will get into the engine and damage it. Always stop the engine before carrying out these operations. When using compressed air, there is a danger that dirt may be blown around and cause serious injury. Always use protective glasses, dust mask, and other protective equipment. Remark When the yellow piston of the dust indicator enters the red range (7.5 kPa) or the air cleaner clogging caution lamp of the machine monitor lights up, clean the air cleaner element. For inspection method, see “Check Air Cleaner” on page 2-86.. Cleaning Outer Element 1.

Stop the engine. 2. Open the engine side cover on the right side of the chassis. 3. Remove three clips (1), then remove cover (2). Remark When cleaning just the outer element, do not remove inner element (4). If it is removed, dust will enter and cause engine problems. The inner element cannot be cleaned. When replacing the outer element, you must replace the inner element at the same time. See “Replacing Element” on page 3-28. 4. Remove outer element (3). 5. Clean the interior of the air cleaner body, cover (2), and evacuator valve (5). 3-26 WA380-6