Komatsu — Clean Element in Air Conditioner Recirculation Filter

MAINTENANCE 5. If any of the following occurs, ask the Komatsu distributor in your territory to replace the belts with new ones: The fan belt has elongated, leaving little allowance for adjustment. A cut or crack is found on the belt. Slipping or creaking sound is heard coming from the belt. If you have replaced the V-belt, operate the machine for one hour and then adjust the belt again. The V-belt elongates when first used. Check for Loose Wheel Hub Nuts, Tighten If wheel hub bolts (1) are loose, tire wear will increase and accidents might happen. 1. Check for loose nuts and tighten, if necessary. When checking for loose nuts, always turn the nuts in the tightening direction.

Tightening torque:. . . . . . . . 825 – 030 N•m (608.49 – 759.69 lbf ft) 2. If any stud bolt is broken, replace all the stud bolts for that wheel. Clean Element in Air Conditioner Recirculation Filter 1. Loosen knob (1), then remove filter inspection cover (2). 2. Remove filter (3) in the direction shown by the arrow. 3. Direct dry compressed air (less than 0.69 MPa (7 kg/cm 2 ) [100 psi] to the element from inside along its folds, and then direct it from outside along its folds and again from inside. 4. Replace the filter with a new part if the clogging cannot be removed with compressed air, or if it has been used for one year.

Remark If the filter becomes clogged, the air flow will be reduced and there will be an abnormal noise from the air conditioner unit. 3-56 WA380-6