SP001727 Electrical System Page 44 Failure Information Code at Machine Side Code Failure Component Measuring Points Correct Value Remarks Active Passive V201 Gauge Panel Communication Error CN7-4 CN7-5 - R = 60 ±5 Ω It is a composite resistance of CAN line. This value has to be measured by connected condition of CAN line. V202 Ecu Communication Error CN4-4 CN4-5 - R = 60 ±5 Ω V210 Pump P/V CN1-10 CN1-21 - R = 18 ±2 Ω (25°C (77°F)) Pump proportional pressure reducing valve. V211 Cooling Fan P/V - - N.A. V212 Flow Control P/V CN1-19 CN1-20 - R = 14 ±2 Ω (25°C (77°F)) Flow control proportional pressure reducing valve.
V213 Relief Pressure Up S/V CN1-1 CN1-11 V = V volt (Note _ 4.) R = 26.2 ±2 Ω (25°C (77°F)) Breaker/boost/ shear selector switch has to be selected as a boost function and the boost switch on the right-hand joystick is "ON" status. V214 High Speed S/V CN1-1 CN1-12 V = V volt _ R = 26.2 ±2 Ω (25°C (77°F)) Voltage is only measured when the pressure switch (Py) is turned "ON." V215 Swing Priority S/V CN1-1 CN1-13 V = V volt _ R = 26.2 ±2 Ω (25°C (77°F)) Work mode has to be selected as a trenching mode. V216 Reverse Fan Speed S/V - - N.A. V217 Starter Relay CN1-1 CN1-15 V = V volt _ - It has to be measured in engine start up state. V218 After Heat Relay 1-16 1-04 - - N.A.