MAN — Changing impeller of raw water pump

Changing impeller of raw water pump Fig. 5 Pull out impeller, using a suitable extractor (avail- able from the manufacturer of the raw-water pump). 4 Fig. 6 Pull out impeller together with the cam, using pliers. 5 Fig. 7 Installation is to be carried out in reverse se- quence. Apply sealant to eccentric before installing it. Lightly coat new impeller with vaseline prior to its installation. Dry running will destroy the impeller. Fill pump with water prior to operation. Check for leaks. 6 69