MAINTENANCE STANDARD WATER PUMP, THERMOSTAT WATER PUMP, THERMOSTAT (WITH SEPARATE TYPE WATER SEAL, INTEGRATED BEARING, SHAFT) Unit: mm 95-2 SERIES 14-15 14-15 1 No. Check item Criteria Remedy 1 Clearance of impeller body Standard clearance: 0.3 – 2.0 Replace 2 Interference between shaft and fan pulley boss Standa size 18 rd Tolerance Shaft Hole Standard interference Hole 0 –0.013 –0.066 –0.082 0.053 – 0.082 3 Interference between shaft and body 42 0 –0.013 –0.025 –0.046 0.012 – 0.046 4 Interference between shaft and impeller 12 0 –0.013 –0.035 –0.062 0.022 – 0.062 5 Curvature of shaft Repair limit: Runout at face A: 0.1 6 Wear of seal of water seal ring Repair limit: Dimension A:
0 7 Thermostat Cracking temperature: 82 ± 2°C Fully open: Shall open fully when immersed in hot water bath at temperature between 95°C and 77°C for 4 – 5 minutes (when immersed in hot water bath at 95°C for 4 – 5 minutes)) Fully open temperature: 95°C Fully open lift: Min. 8