Return to Master Table of Contents S0605050K Page 8 Air Conditioner TEMPERATURE LEVEL CONTROL AND DISPLAY Step LED 1 LED 2 LED 3 LED 4 LED 5 LED 6 LED 7 Position Sensor Voltage Remark 0 Green Green Green Green Green Green Green 4.50 V ±0.2 MAX.
COOL 1 Green Green Green Green Green Green Green 4.33 V ±0.2 2 Green Green Green Green Green Green Green 4.15 V ±0.2 3 Red Green Green Green Green Green Green 3.98 V ±0.2 4 Red Green Green Green Green Green Green 3.80 V ±0.2 5 Red Green Green Green Green Green Green 3.63 V ±0.2 6 Red Red Green Green Green Green Green 3.46 V ±0.2 7 Red Red Green Green Green Green Green 3.28 V ±0.2 8 Red Red Green Green Green Green Green 3.11 V ±0.2 9 Red Red Red Green Green Green Green 2.93 V ±0.2 10 Red Red Red Green Green Green Green 2.76 V ±0.2 11 Red Red Red Green Green Green Green 2.59 V ±0.2 12 Red Red Red Red Green Green Green 2.41 V ±0.2 13 Red Red Red Red Green Green Green 2.24 V ±0.2 14 Red Red Red Red Green Green Green 2.07 V ±0.2 15 Red Red Red Red Red Green Green 1.89 V ±0.2 16 Red Red Red Red Red Green Green 1.72 V ±0.2 17 Red Red Red Red Red Green Green 1.54 V ±0.2 18 Red Red Red Red Red Red Green 1.37 V ±0.2 19 Red Red Red Red Red Red Green 1.20 V ±0.2 20 Red Red Red Red Red Red Green 1.02 V ±0.2 21 Red Red Red Red Red Red Red 0.85 V ±0.2 22 Red Red Red Red Red Red Red 0.67 V ±0.2 23 Red Red Red Red Red Red Red 0.50 V ±0.2 MAX.
HOT