Return to Master Table of Contents S0605050K Page 14 Air Conditioner TROUBLESHOOTING Refrigerant Pressure Check LO HI HDA6074L Figure 13 1. Open all doors and windows. 2. Install manifold gauge set. 3. Start engine and maintain engine speed at 1,800 - 2,000 rpm. 4. Check high / low pressure of refrigerant. 1 High Pressure: 8 - 10 kg/cm2 (114 - 142 psi) Low Pressure: Approximately 1 kg/cm2 (14 psi) Possible Cause: Low Refrigerant Level Step Inspection Item Remedy 1 Check for traces of refrigerant oil. Yes No Reassemble using correct tightening torque. Go to next step. 2 Using a leak detection device or soapy water check for refrigerant leakage at all major components and joints.
Yes No Repair leaking component. Recharge system to correct pressure. 2 High Pressure: Over 23 kg/cm2 (327 psi) Low Pressure: Approximately 2.5 - 3.0 kg/cm2 (36 - 43 psi) Possible Cause: Overcharge, Frost on condenser Step Inspection Item Remedy 1 Check for condenser pin damage or contamination. Yes No Clean, repair or replace condenser. Refrigerant overcharge.