Return to Master Table of Contents 3. If refrigerant does not flow freely into system, try starting engine first before operating air conditioner. Temperature control switch setting: Maximum Cooling Blower Speed Setting: Hi (3 step) Engine Speed: 1,300 - 1,500 rpm WARNING! When charging refrigerant system with the engine running; Always keep refrigerant supply container in the upright position. Never open the high side pressure valve. 4. Open the manifold gauge low side valve and charge system to standard capacity. NOTE: These standards are for outside temperatures between 30˚ - 35˚C (86˚ - 95˚F). The gauge readings may vary for extreme temperature conditions. WARNING!
When outside temperature is low, warm the refrigerant supply container with warm water not exceeding 40˚C (104˚F). Do not allow water to come in contact with the charging adapter valve handle. When outside temperature is high, cool off refrigerant supply container and condenser to aid the refrigerant charging process. 5. Close low pressure side valve. 6. Shut off engine and close refrigerant supply container adapter valve. Disconnect manifold gauge hoses from vehicle. S0605050K Page 24 Air Conditioner Gauge Dial Standard Reading High Side Gauge 13 - 20 kg/cm2 (185 - 285 psi) Low Side Gauge 1.5 - 3.5 kg/cm2 (21 - 50 psi)