daewoo Mega 500-V — Transmission and Torque Converted (ZF 4WG-310)

12. Tilt plate carrier 90˚. 13. Loosen slotted nut. CAUTION! Slotted nut is secured with Loctite. To prevent a damage of the thread, heat the slotted nut before loosen it (about 120˚C (248˚F)). Figure 165 14. Pull tapered roller bearing from plate carrier. Figure 166 15. Pull spur gear KV from plate carrier. Figure 167 16. Remove shim and ring. Figure 168 S0607080K Page 80 Transmission and Torque Converter (ZF 4WG-310)