daewoo Mega 500-V — Transmission and Torque Converted (ZF 4WG-310)

1. Check plate clearance K1 = 2.6 - 2.8 mm (0.1024 - 0.1102 in) (Figure 274 - Figure 276). NOTE: To ensure a faultless measuring result, install the plates for the present without oil. A. Install plate pack according to Figure 273. Figure 274 B. Introduce the end shim and secure it using snap ring. Figure 275 C. Press the end shim on with about 100 N (10 kg) and set the dial indicator to "Zero." D. Now, press the end shim against the snap ring (upward), and read the plate clearance on the dial indicator. E. After the performed adjustment of the plate clearance, disassemble the plate pack, oil plates according to ZF- List of lubricants TE-ML 03 and install them again.

Figure 276 IMPORTANT In case of deviations from the required plate clearance = 2.6 - 2.8 mm (0.1024 - 0.1102 in), correct with corresponding inner plate Item 6 (optional 2.5 - 3.5 mm (0.0984 - 0.1378 in)) or and snap ring Item 7 (optional). S0607080K Page 118 Transmission and Torque Converter (ZF 4WG-310)