daewoo Mega 500-V — Transmission Error Condes (ZF)

S0607900C Page 10 Transmission Error Codes (ZF) TABLE OF FAULT CODES The fault codes shown in this table are a complete list of codes that are common to more than one version of the transmission. Some of the versions are 4WG (four speed) and 6WG (six speed). NOTE: This fault code list is valid for the ZF Software Versions V 53.x to V58.0 Fault Code (hex) Meaning of the Fault Code (Possible reason for fault detection.) Reaction of the TCU Possible Steps to Repair Remarks 11 Logical error at gear range signal. TCU detected a wrong signal combination for gear range. • Cable from shift lever to TCU is broken. • Cable is defective and is contacted to battery voltage or vehicle ground.

• Shift lever is defective. TCU shifts transmission to neutral. OP-Mode: transmission shut down. Check cables from TCU to shift lever. Check signal combinations of shift lever positions for gear range. Failure cannot be detected in systems with DW2/DW3 shift lever. Fault is taken back if TCU detects a valid signal for position. 12 Logical error at direction select signal. TCU detected a wrong signal combination for direction. • Cable from shift lever to TCU is broken. • Cable is defective and is contacted to battery voltage or vehicle ground. • Shift lever is defective. TCU shifts transmission to neutral. OP-Mode: transmission shut down. Check cables from TCU to shift lever.

Check signal combinations of shift lever positions F-N-R. Fault is taken back if TCU detects a valid signal for direction at shift lever. 17 ** S.C. to ground at Solenoid LIS1 (Function No. 1). TCU detected a wrong voltage at output pin, that looks like a S.C. to vehicle ground. • Cable is defective and is contacted to vehicle ground. • Solenoid LIS1 (Function No. 1) device has an internal defect. • Connector pin is contacted to vehicle ground. Customer specific. Check cable from TCU to Solenoid LIS1 (Function No. 1) device. Check connectors from Solenoid LIS1 (Function No. 1) to TCU. Check resistance of Solenoid LIS1 (Function No. 1) device.

1) See “Measurement of Resistance at Actuator/sensors and Cable” on page 35. * Only Mega 400-III PLUS ** Only Series "V" Gray shaded boxes are error codes for other applications. They are only given for general reference purposes.