Daewoo Heavy Industries Mega 500-V — Transmission Error Condes (ZF)

S0607900C Page 17 Transmission Error Codes (ZF) Fault Code (hex) Meaning of the Fault Code (Possible reason for fault detection.) Reaction of the TCU Possible Steps to Repair Remarks 3C Logical error at output speed input. TCU measures a output speed over a threshold and at the next moment the measured speed is zero. • Cable / connector is defective and has bad contact. • Speed sensor has an internal defect. • Sensor gap is incorrect. Special mode for gear selection. OP-Mode: substitute clutch control. If a failure is existing at turbine speed, TCU shifts to neutral. OP-Mode: limp home. Check cable from TCU to sensor. Check connectors. Check speed sensor. Check sensor gap.

This fault is reset after power up of TCU. 3E Output speed zero doesn’t fit to other speed signals. If transmission is not neutral and the shifting has finished, TCU measures output speed zero and turbine speed or internal speed not equal to zero. • Speed sensor has an internal defect. • Sensor gap is incorrect. Special mode for gear selection. OP-Mode: substitute clutch control. If a failure is existing at turbine speed, TCU shifts to neutral. OP-Mode: limp home. Check sensor signal of output speed sensor. Check sensor gap of output speed sensor. Check cable from TCU to sensor. This fault is reset after power up of TCU. 71 S.C. to battery voltage at clutch K1.

The measured resistance value of valve is out of limit, voltage at K1 valve is too high. • Cable / connector is defective and has contact to battery voltage. • Cable / connector is defective and has contact to another regulator output of TCU. • Regulator has an internal defect. TCU shifts to neutral. OP-Mode: limp home. If failure at another clutch is pending. TCU shifts to neutral. OP-Mode: TCU shut down. Check cable from TCU to gearbox. Check connectors from TCU to gearbox. Check regulator resistance. 1) Check internal wire harness of gearbox. 1) See “Measurement of Resistance at Actuator/sensors and Cable” on page 35.

* Only Mega 400-III PLUS ** Only Series "V" Gray shaded boxes are error codes for other applications. They are only given for general reference purposes.